Main station|Member Center|Save the desktop|Mobile browsing
Ordinary Member

南阳天中电器设备有限公司

节能电力变压器、高低压配电柜、高压计量箱和预装式变电站生产销售、五金电料、电...

sell
  • There is no classification
contact
  • Contact:李洋
  • Phone:0377-62138788
search
 
link
  • There is no link yet
home > sell > KYN28 high voltage switch cabinet
KYN28 high voltage switch cabinet
products: Views:212KYN28 high voltage switch cabinet 
brand: 宛电牌
产品型号: KYN28
额定电压: 10KV
额定频率: 50HZ
price: 3000.00元/台
MOQ: 1 台
Total supply: 10000 台
Delivery date: Shipped within 3 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2015-07-03 11:42
 
Details
High-voltage switchgear
Detailed description of technical performance
Overview
The shell of the product is completely made of aluminum-zinc plate that is processed by CNC machine tools and multiple bends and then assembled with bolts. It has high The mechanical strength effectively ensures the neatness and beauty of the product. The cabinet door is spray-coated with strong impact resistance and corrosion resistance. The protection level of the product shell.
The main switch of this product is selected from the well-known foreign brand Schneider. It can also be equipped with a variety of domestic series vacuum circuit breakers (such as etc.) to replace similar foreign products.
No matter what kind of circuit breaker is selected, the air insulation distance of the bare conductor can be guaranteed to be larger than that of the composite insulation. The circuit breakers have the unique advantages of long life, high reliability, less maintenance and small size.
The switch cabinet is composed of two parts: a fixed cabinet body and a removable part (referred to as a handcart). The outer shell of the cabinet body and the metal partitions of each functional unit are connected by bolts. The protection level of the switch cabinet shell is the protection level when the circuit breaker chamber door is opened. The switch cabinet can be equipped with a vacuum circuit breaker handcart or a fixed load switch.
Environmental conditions for use
Environmental conditions
Height
High temperature + ℃
Low temperature ℃
Large daily temperature difference
Humidity (in ℃)
Main technical parameters and requirements
Main technical parameters
Constant voltage
For constant current, see special technical specifications
Fixed frequency
Fixed short-time breaking See the special technical specifications for the current
See the special technical specifications for the clock rated short-time withstand current
See the special technical specifications for the fixed peak withstand current
Power supply
Requirements
Gas insulation Distance from phase to earth>Phase to phase>
External insulation creepage ratio distance of each component of voltage switch cabinet and its supporting insulating parts
Pure porcelain insulation>/Organic insulation>/
Two structural characteristics
Shell and partitions
The shell and partitions of the switch cabinet are assembled from aluminum-zinc-coated steel plates after CNC machine tool processing and multiple bending. Therefore, the assembled switch cabinet can maintain uniformity in size. It has strong anti-corrosion and anti-oxidation effects, and has higher mechanical strength than equivalent steel plates. The switch cabinet is divided by partitions into a handcart room, a busbar room, a cable room, a relay instrument room, and the shell of each compartment is independently grounded. The door of the switch cabinet adopts plastic spraying process to make its surface resistant to impact and corrosion, ensuring a beautiful appearance.
Handcart
The handcart frame is made of steel plates processed by CNC machine tools and then riveted (welded). According to the purpose of use, handcarts can be divided into circuit breaker handcarts, voltage transformer handcarts, metering handcarts, isolation cars, etc. The height and depth of all types of handcarts are unified, and handcarts of the same specifications are completely interchangeable. The handcart has an isolation/test position and a working position in the cabinet. Each position is equipped with a positioning device to ensure that the handcart cannot be moved casually when it is in the above specific position. When moving the handcart, the position lock must be released. Circuit breaker handcart The circuit breaker must be opened before moving, and when the circuit breaker is in the closed state, the circuit breaker truck cannot be moved (cranked out).
Compartments in the switch cabinet
Circuit breaker compartment
Guide rails for the circuit breaker handcart to slide are installed in the circuit breaker room. The handcart can move between working position and test/isolation position. The movable curtain panel is made of metal plate and installed on the rear wall of the handcart room. When the handcart moves from the isolation/test position to the working position, the movable curtain plate installed on the static contact automatically opens. When the handcart is moved in the opposite direction, the movable curtain plate automatically closes and seals the static contact box, thereby ensuring Operators should not touch live objects. The handcart is operated when the door of the switch cabinet is closed. Through the observation window, you can see the position of the handcart in the cabinet, and you can also see the (circuit breaker closing)/(circuit breaker opening) operating buttons on the handcart. and/mechanical position indicator and energy storage/release condition indicator.
Withdrawable circuit breaker handcart
The frame is assembled from steel plates, and the handcart is equipped with a vacuum circuit breaker and other auxiliary equipment. The primary movable contact with a spring contact system is installed on the outlet terminal of the circuit breaker through an arm. The control button of the circuit breaker operating mechanism and the opening and closing position indication are all located on the handcart panel to facilitate operation. When the handcart enters the switch cabinet and reaches the isolation/test position, the handcart shell is reliably connected to the switch cabinet grounding system, and the instrument protection and control circuits are also connected to the switch cabinet through the secondary plug.
Busbar compartment
The busbar is supported by insulating sleeves and led from one switch cabinet to another switch cabinet, and is connected to the static contact box through branch busbars. The main busbar and tie busbar are rounded copper bars with rectangular cross-sections. When used for large current loads, two rectangular bus bars are required. All busbars are covered with heat shrink tubing. The fully insulated busbar system greatly reduces the probability of internal failures in the busbar room. The busbar rooms that arrange each cabinet are isolated from each other. If an internal fault occurs in the cabinet, free gas can be released through the pressure relief plate, and the free gas will not be introduced into adjacent cabinets to avoid the spread of the fault.
Cable Compartment
Current transformers and voltage transformer grounding switches can be installed on the rear wall of the cable compartment, and lightning arresters can also be installed in the cable room. After the handcart reaches the isolation position, operate the grounding switch (if any) and the front door can be opened or the horizontal partition is removed. Then the construction workers can enter the switch cabinet from the front to install cables. There are specific cable connection conductors in the cable room, which can be connected together. A single-core cable is connected, and a removable metal sealing plate is provided at the lower part to facilitate on-site construction.
Instrument Compartment
The instrument compartment can be equipped with protective components such as relays, instrument live monitoring indicators, and secondary equipment with special requirements. The control wires are laid in wire troughs with sufficient space and metal covers. The left wire trough is reserved for the introduction and extraction of the control small busbar. There are also small busbar crossing holes left on the side panels of the instrument compartment for construction.
The switch cabinet with interlocking device to prevent misoperation has a reliable interlocking device, which provides reliable safety protection for operators and equipment, and has complete five-proof functions.
Nanyang Tianzhong high voltage cabinet
Nanyang Tianzhong high and low voltage complete switch cabinet
High voltage switch cabinet
Switch cabinet
High voltage complete equipment
Nanyang high voltage cabinet
Henan high voltage cabinet
High voltage cabinet quotation
High and low voltage complete sets of equipment manufacturers
Nanyang high voltage cabinet manufacturers
Henan high voltage cabinet production and sales
Where to find Nanyang Tianzhong high and low voltage complete sets of switches Cabinet
High and low voltage complete sets are of good quality
Where are the high and low voltage complete sets at low prices
High voltage cabinet specifications and models
High voltage cabinet technical parameters and performance characteristics
High voltage distribution cabinet
High and low voltage complete sets of equipment
Fixed switch cabinets
Series of high voltage switch cabinets
What are the more famous manufacturers or suppliers
Henan electrical complete sets
Henan high and low voltage distribution equipment Which electrical cabinet manufacturer is the best
  Internal environmental conditions
Height<
High temperature +℃
Low temperature℃
Large daily temperature difference
Humidity (at ℃)
Main technical parameters and requirements
Main technical parameters
Constant voltage
For constant current, see special technical specifications
Fixed frequency
Fixed short time See the special technical specifications for the breaking current
See the special technical specifications for the rated short-time withstand current
See the special technical specifications for the fixed peak withstand current
Control power supply
Requirements
Air insulation distance from phase to phase>Phase to phase>
External insulation creepage ratio distance of each component of the pressure switch cabinet and its supporting insulating parts
Pure porcelain insulation>/Organic insulation>/
Two structural characteristics
br/> Shell and partitions
The shell and partitions of the switch cabinet are assembled from aluminum-zinc-coated steel plates after CNC machine tool processing and multiple bending. Therefore, the assembled switch cabinet can maintain uniformity in size. . It has strong anti-corrosion and anti-oxidation effects, and has higher mechanical strength than equivalent steel plates. The switch cabinet is divided by partitions into a handcart room, a busbar room, a cable room, a relay instrument room, and the shell of each compartment is independently grounded. The door of the switch cabinet adopts plastic spraying process to make its surface resistant to impact and corrosion, ensuring a beautiful appearance.
Handcart
The handcart frame is made of steel plates processed by CNC machine tools and then riveted (welded). According to the purpose of use, handcarts can be divided into circuit breaker handcarts, voltage transformer handcarts, metering handcarts, isolation cars, etc. The height and depth of all types of handcarts are unified, and handcarts of the same specifications are completely interchangeable. The handcart has an isolation/test position and a working position in the cabinet. Each position is equipped with a positioning device to ensure that the handcart cannot be moved casually when it is in the above specific position. When moving the handcart, the position lock must be released. Circuit breaker handcart The circuit breaker must be opened before moving, and when the circuit breaker is in the closed state, the circuit breaker truck cannot be moved (cranked out).
Compartments in the switch cabinet
Circuit breaker compartment
Guide rails for the circuit breaker handcart to slide are installed in the circuit breaker room. The handcart can move between working position and test/isolation position. The movable curtain panel is made of metal plate and installed on the rear wall of the handcart room. When the handcart moves from the isolation/test position to the working position, the movable curtain plate installed on the static contact automatically opens. When the handcart is moved in the opposite direction, the movable curtain plate automatically closes and seals the static contact box, thereby ensuring Operators should not touch live objects. The handcart is operated when the door of the switch cabinet is closed. Through the observation window, you can see the position of the handcart in the cabinet, and you can also see the (circuit breaker closing)/(circuit breaker opening) operating buttons on the handcart. and/mechanical position indicator and energy storage/release condition indicator.
Withdrawable circuit breaker handcart
The frame is assembled from steel plates, and the handcart is equipped with a vacuum circuit breaker and other auxiliary equipment. The primary movable contact with a spring contact system is installed on the outlet terminal of the circuit breaker through an arm. The control button of the circuit breaker operating mechanism and the opening and closing position indication are all located on the handcart panel to facilitate operation. When the handcart enters the switch cabinet and reaches the isolation/test position, the handcart shell is reliably connected to the switch cabinet grounding system, and the instrument protection and control circuits are also connected to the switch cabinet through the secondary plug.
Busbar compartment
The busbar is supported by insulating sleeves and led from one switch cabinet to another switch cabinet, and is connected to the static contact box through branch busbars. The main busbar and tie busbar are rounded copper bars with rectangular cross-sections. When used for large current loads, two rectangular bus bars are required. All busbars are covered with heat shrink tubing. The fully insulated busbar system greatly reduces the probability of internal failures in the busbar room. The busbar rooms that arrange each cabinet are isolated from each other. If an internal fault occurs in the cabinet, free gas can be released through the pressure relief plate, and the free gas will not be introduced into adjacent cabinets to avoid the spread of the fault.
Cable Compartment
Current transformers and voltage transformer grounding switches can be installed on the rear wall of the cable compartment, and lightning arresters can also be installed in the cable room. After the handcart reaches the isolation position, the grounding switch (if any) is operated. The front door can be opened or the horizontal partition is removed. Then the construction workers can enter the switch cabinet from the front to install cables. There are specific cable connection conductors in the cable room, which can be connected together. A single-core cable is connected, and a removable metal sealing plate is provided at the lower part to facilitate on-site construction.
Instrument Compartment
The instrument compartment can be equipped with protective components such as relays, instrument live monitoring indicators, and secondary equipment with special requirements. The control wires are laid in wire troughs with sufficient space and metal covers. The left wire trough is reserved for the introduction and extraction of the control small busbar. There are also small busbar crossing holes left on the side panels of the instrument compartment for construction.
The switch cabinet with interlocking device to prevent misoperation has a reliable interlocking device, which provides reliable safety protection for operators and equipment, and has complete five-proof functions.
Request for quotation
A total of0articles  Related Comments: